Vertical Floor-standing Medical Autoclaves without drying

AES-MD Series
Sterilization of non-wrapped solid products, as clinical instruments.
Sterilization of distilled water and non-medicinal liquid preparations, in open bottles.

Request a Quotation

Vertical Floor-standing Medical autoclaves without drying (33-175L) – AES-MD Series

Features

  • Sterilization chamber made of AISI-316L stainless steel. External housing made of AISI-304 stainless steel.
  • Equipment controlled by digital PID microprocessor, with 4 predefined and 6 editable programs, adjustable by time, temperature and type of cycle (solids or liquids).
  • Alphanumeric LCD screen that shows sterilization parameters, alerts and errors.
  • Manual steam release push-button.
  • Manual drain valve.
  • Manual filling of the sterilization chamber with water.
  • Protecting grid for the heater element.
  • Cycle time range: 1-250 minutes.

 

Advantages

  • Agar mode (40 to 80 ºC) and programs for liquids.
  • Heart probe optional.
  • Optional inlet in chamber for an external validation probe.
  • Programmable auto-start (24 h).
  • Connection to PC.
  • RS-232 port to connect to PC or printer.
  • Control software optional.
  • Optional integrated or external printers.

Safety

  • Safety valve and thermostat.
  • Hydraulic lid blocking system while positive pressure exists in the chamber.
  • Open lid sensor.

 

Special models

  • Available models with increased power to 3200W (AES-28-MD), 6000W (AES-50-MD, AES-75-MD and AES-110-MD) and 9000W (AES-110-MD and AES-150-MD). The equipments with increased power allow to reduce the total sterilization cycle time, by shortening the heating phase particularly in autoclaves with a high workload.
 


ModelsAES-28-MDAES-50-MDAES-75-MDAES-110-MDAES-150-MD
Chamber volume total/usable33/31 L55/50 L79/75 L115/110 L175/153 L
Usable chamber dimensions Ø x H300 x 440 mm300 x 710 mm400 x 600 mm400 x 850 mm500 x 780 mm
Sterilization chamber water tank volume3 L3 L5‚5 L5‚5 L9‚5 L
Exterior dimensions L x D x H505 x 580 x 1110 mm505 x 580 x 1290 mm610 x 700 x 1185 mm610 x 700 x 1435 mm750 x 820 x 1400 mm
Loading height795 mm975 mm870 mm1120 mm1085 mm
Power 2000 o 3200 W3200 o 6000 W3200 o 6000 W4500‚ 60000 o 9000 W6000 o 9000 W
Gross weight 75 Kg90 Kg115 Kg135 Kg230 Kg
Voltage*230V 16A230V 16A230V 16A o 400V 32A400V 32A400V 32A
Frequency 50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz
Adjustable sterilization temperature 100-134 ºC 100-134 ºC 100-134 ºC 100-134 ºC 100-134 ºC
Adjustable sterilization time 1-250 min1-250 min1-250 min1-250 min1-250 min
Max. pressure 2‚1 Barg 2‚1 Barg 2‚1 Barg 2‚1 Barg 2‚1 Barg

*Other voltages available under request. Special models with augmented power may operate with other voltages.

All RAYPA medical autoclaves comply with ISO 13485: 2016 certification.

 

ACCESSORIES

CV
Stainless steel wire basket

TR
Liquid collector tray for wire baskets

CCI
Unperforated stainless steel baskets for waste sterilization

TBE
Stainless steel “schimmelbusch” drum for medical instruments

ELEV-CLAV
Baskets crane

MOB-LIFT
Mobile baskets crane

CEP
Stainless steel cylinders for Petri dishes sterilization

CEPP
Stainless steel cylinders for pipette sterilization

SRA
Support with height adjustable trays

PT-2
Flexible “heart” probe PT-100

PRENSACLAV
For autoclave calibration

IT
Integrated thermal printer

IT-M
Integrated dot matrix printer

ITS
Dot matrix table top printer

EXT-TP
External probe adapter

ECOPUR-500
Eco-efficient water purifier

4WHBR
Set of 4 wheels - 2 with brakes

TR-TR
Transport trolley

TANK-AE
Condensates bottle

TEST-CT
Sterilization control tape

SW7000
PC connection