Vertical Floor-standing Medical Multipurpose Autoclaves

TLV-MD Series Basic

Multi-purpose autoclave for sterilizing solids and liquids
The TLV series are designed to cover the basic sterilization needs in all type of laboratories of industries and educational institutions.


STERILIZATION WITH TOTAL CONNECTIVITY

RAYPACLOUD: Storage and management in the cloud with access from different devices.
RAYPASUPPORT:
Assistance, monitoring, diagnosis and remote maintenance.
RAYPACONTROL:
Panel PC, user interaction with the system in an intuitive, comfortable and simple way.

Contact

SMART AUTOCLAVES TLV-MD Basic Series

Features

  • Integrated steam generator (separated into the housing) with automatic filling.
  • 7” capacitive colour touch screen.
  • Connectivity to PC, cloud, intranet, LIMS.
  • Bacteriological filter.
  • Automatic block/unblock system 
with mechanical assisted door
  • Casters with brake.
  • Filtration of exhaust gases.
  • Water cooled discharge.

Advantages

  • Fractioned vacuum (from 0 to 1 pre-vacuums).
  • Final temperature maintenance for liquid programs (40ºC-90ºC).
  • Optional main and secondary flexible heart probe.
  • Programmable timer start (date and time).
  • Unlimited data storage. Connection to RAYPAcloud.
  • Optional integrated or external printer.
  • Optional external barcode printer.
  • Automatic door closing system.
  • Bacteriological filtration for inlet and outlet air.
  • Easy cleaning of the sterilization chamber.
  • Compliance with FDA 21 CFR Part 11 and GMP Annex 11.

Safety

  • Safety valve.
  • Safety thermostat.
  • Door opening prevention system.
  • Open lid sensor.
  • Water level detector inside the steam generator.
TLV-50-MD TLV-75-MD TLV-110-MD TLV-150-MD
Chamber dimensions Ø x H usable 400 x 450 mm 400 x 650 mm 500 x 600 mm 500 x 850 mm
Chamber volume total / usable 58 / 56 L 83 / 81 L 124 / 118 L 169 / 155 L
External dimensions L x D x H 610 x 870 x 1000 mm 610 x 870 x 1080 mm 710 x 970 x 1320 mm 710 x 970 x 1400 mm
Weight 140 Kg 150 Kg 195 Kg 210 Kg
Power 3600 W 3600 W 9000 W 9000 W
Electrical voltage * 230 (1P+N+E) V 230 (1P+N+E) V 400 (3P+N+E) V 400 (3P+N+E) V
Frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
Working temperature range 100 – 140 ºC 100 – 140 ºC 100 – 140 ºC 100 – 140 ºC
Maximum working pressure 2‚6 barg 2‚6 barg 2‚6 barg 2‚6 barg
Maximum design Temperature / Pressure 143 ºC / 2‚9 barg 143 ºC / 2‚9 barg 143 ºC / 2‚9 barg 143 ºC / 2‚9 barg

* Ask for other voltages